ASTM Standard
Title
Description
Final Result
ASTM
C-1452
Standard Specification for Reinforced Autoclaved Aerated Concrete (AAC) Elements Standard Covers Loadbearing and Non-loadbearing Reinforced AAC Floor, Roof, Wall and Stair Elements
Compression Strength, Density, Reinforcing Specifications, Testing Requirements
ASTM
C-1386
Standard Specification AAC Units Standard Covers Loadbearing and Non-loadbearing AAC Units
Compressive Strength of AAC 580-725 psiDry Density 31-50 pcf
ASTM
E-119
Fire Test of Building Constructions and Materials Fire Test of Wall Assemblies (Load/Non-loadbearing) and Hose Stream Test. Fire Test of Floor/Roof Assembly
UL Classification Fire Ratings for Blocks, Lintels, Wall/Floor/Roof Panels Containedin UL Fire Resistance Directory
ASTM
E-90
Sound Transmission Loss Test Airborne Sound Transmission Test on Wall/Roof Assemblies
STC Ratings of AAC AssembliesUL Certification
ASTM
E-492
Impact Sound Transmission Test Impact Sound Transmission Test on Wall/Roof Assemblies
IST Ratings AAC Roof/Floor AssembliesUL Certification
ASTM
E-72
Compression and Transverse Load Testing of Panels Testing Wall/Floor/Roof Panels for Compression/Transverse Loads
Load Table Ratings of Wall/Floor/Roof Panels
ASTM
C-469
Modulus of Elasticity Compression Testing Expressed Exponentially
Stress Strain Curve of AAC in Compression
ASTM
E-78
Flexural Strength Flexural Test of AAC Units
Flexural Strength of AAC Products
ASTM
E-518
Flexural Bond Strength of Masonry Assembly of Masonry Units Constructed as Beams
Flexural Bond Strength of AAC Products

ASTM
E-519

Diagonal Tension Test of Masonry Assemblies Full Scale Walls
Diagonal Tension of AAC
ASTM
E-447
Compressive Strength Testsof Masonry Prisms Masonry Units Assembled in Stack Bond for Compression Testing
Compressive Strength of AAC
ASTM
C-177-85
Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded Hot Plate Apparatus A Portion of AAC Material of 12” x 12”and 1” thick is Placed in the Guarded Hot Plate. It is Subjected to a Heat Source and Temperature Measurements are Made Until A Steady State is Reached.
Experimental Value of Thermal Conductivity (K)
ASTM
E-514
Test for Water Penetration and Leakage Through Masonry Full Scale Wall Assemblies Subjected to Water Under Pressure Exposure
Zero Water Penetration or Leakage Through AACMasonry Assembly After 8 Hrs @ 62.5 mph

 

 
 
 
For more information contact AIRCRETE TECHNOLOGIES, LLC / AACS
6085 Feather Lane
Sanford, FL. 32771
Phone 407-320-9989 Fax 407-323-8615

or contact us by e-mail: info@aacsinc.com